Table of Contents

  • Notices and Trademarks
  • Open this section 1. Introduction
    • Open this section 1.1. Installing Chenomx NMR Suite
      • Windows (64-bit)
      • Windows (32-bit)
      • Mac OS X
      • Linux (64-bit)
      • Linux (32-bit)
    • 1.2. Running Chenomx NMR Suite
    • 1.3. Software Updates
    • 1.4. Tutorial and Sample Files
  • Open this section 2. Handling Samples and Spectra
    • Open this section 2.1. Sample Preparation
      • Preparing Filter Tubes for Sample Filtration
      • Filtering the Sample through Microcentrifuge Filter Tube
      • Internal Standard Solution
    • Open this section 2.2. Spectral Data Acquisition
      • Pulse Sequences
      • Required NMR Parameters
    • Open this section 2.3. Spectral Data Processing
      • Data Processed with Other Software
  • Open this section 3. Common Tasks
    • 3.1. Processing a Spectrum
    • 3.2. Profiling a Spectrum
    • 3.3. Identifying Compounds
    • 3.4. Profiling Overlapped Regions in a Spectrum
    • 3.5. Determining Compound Concentrations
  • Open this section 4. The Basics
    • 4.1. Opening Files
    • 4.2. Importing Spectra
    • 4.3. Saving Files
    • 4.4. Closing Files
    • 4.5. Exiting Modules
    • 4.6. Undo and Redo
    • 4.7. Change Columns
    • Open this section 4.8. Sidebar
      • Legend
      • Files
      • Reference Cards
      • Spectrum Details
      • Processing History
      • Compound Sets
      • Simulation
    • 4.9. Spectrum Overlays
    • Open this section 4.10. Spectrum Graph Tools
      • Show Entire Spectrum
      • Set Zoom
      • Undo/Redo Zoom
      • Auto Zoom
      • Increase/Decrease Vertical Zoom
      • Increase/Decrease Horizontal Zoom
      • Spectrum Graph
      • Spectrum Thumbnail
      • Select Region
    • 4.11. Export Spectrum Image
    • 4.12. Copy Spectrum Image to Clipboard
    • 4.13. Display Options
    • 4.14. Preferences
  • Open this section 5. Processor
    • 5.1. Overview
    • Open this section 5.2. Processing Tools
      • Line Broadening
      • Phase Correction
      • Baseline Correction
      • Shim Correction
      • Region Deletion
      • Reverse Spectrum
      • Batch Process
    • Open this section 5.3. Calibration Tools
      • Calibrate CSI
      • Define Custom CSI
      • Calibrate pH
      • Calibration Tool
    • Open this section 5.4. Information Tools
      • Spectrum Details (Sidebar)
      • Processing History (Sidebar)
    • Open this section 5.5. Importing and Exporting Data
      • Batch Import
      • Send to Profiler
      • Export as JCAMP-DX
  • Open this section 6. Profiler
    • 6.1. Overview
    • Open this section 6.2. Profiling Tools
      • Compound Table
      • Custom Colors
      • Pinned Compounds
      • Starred Compounds
      • Remember Selection
      • Quick Searches
      • Concentrations and Compound Fits
      • Fit Automatically
      • Concentration Fitting and Optimization Tool
      • Enforce Transform Windows
      • Scale Concentrations
      • Batch Edit
      • pH Tool
      • Compound Snapper
      • Batch Fit
    • 6.3. Cluster Navigator
    • Open this section 6.4. Compound Set Tools
      • Compound Sets (Sidebar)
    • Open this section 6.5. Importing and Exporting Data
      • Batch Export
      • Export Compound Table
      • Export Profiled Compounds
      • Import Profile
      • Send to Processor
    • 6.6. Spectral Binning
    • Open this section 6.7. Information Tools
      • Legend (Sidebar)
      • Reference Card Panel (Sidebar)
      • Spectrum Details (Sidebar)
      • Concentration Units
  • Open this section 7. Spin Simulator
    • 7.1. Overview
    • Open this section 7.2. Simulating Tools
      • New Simulation
      • Spin Systems
      • Spin Definitions
      • Spin Navigator
      • J-Modifiers
    • Open this section 7.3. Information Tools
      • Spin Definition (Sidebar)
      • Simulation Details
  • Open this section 8. Compound Builder
    • 8.1. Overview
    • Open this section 8.2. Building Tools
      • New Compound
      • Import Simulation
      • Adding Peaks
      • Selecting Peaks and Clusters
      • Delete Selected Peaks
      • Adjusting Peaks
      • Grouping Peaks as a Cluster
      • Optimize Selected Peak Shapes
      • Generate Cluster for Region
      • Transform Windows
      • pH Sensitivities
      • Manage Cluster IDs
      • Cluster Navigator
    • Open this section 8.3. Information Tools
      • Reference Card Panel (Sidebar)
      • Compound Details
      • Information Panel
    • 8.4. Compound Fit Style
  • Open this section 9. Library Manager
    • 9.1. Overview
    • Open this section 9.2. Library Tools
      • Compound Table
      • Quick Searches
      • Add Compounds
      • Export Compounds
      • Send to Compound Builder
      • Remove Compounds
      • Update Compounds
    • Open this section 9.3. Compound Set Tools
      • Compound Sets (Sidebar)
      • Automatic Compound Sets
      • Compound Sets
      • Smart Compound Sets
      • Rename Compound Sets
      • Remove Compound Sets
    • Open this section 9.4. Reference Card Editor
      • Required Details
      • Optional Details
    • Open this section 9.5. Information Tools
      • Reference Card Panel (Sidebar)
Chenomx NMR Suite User Guide logo

Search Results (close)

This is where the search results appear

8.3 Information Tools

While building compound signatures, you can access extended information about common compounds, view and update details associated with the current compound, and more precisely manage peaks and clusters in complex compounds.

Reference Card Panel (Sidebar)

Menu Location View > Sidebars > Left Sidebar > Reference Panel
Icon
Reference Card Panel icon
Menu Location View > Sidebars > Right Sidebar > Reference Panel
Icon
Reference Card Panel icon

The Reference Card Panel Sidebar view displays information specific to the compound matching the Chenomx Compound ID that you have specified in the Compound Details. The displayed information includes a structure image, molecular formula and weight, alternate names and links to external reference sites. You can use this information to better understand the structure and behaviour of a compound as you build its signature.

Related Topics

  • “Reference Cards”

  • “Preferences”

  • “Building Tools”

  • “Compound Details”

Compound Details

Menu Location File > Compound Details...
Icon
Compound Details icon

Using Compound Details, you can associate information with compound signatures that you build. The information that you enter lets you use the signature with appropriate spectra, display correct information in the Reference Card Panel, calculate accurate concentrations, and manage the contents of your compound library effectively.

Table 8.1. Compound Details

Compound Name The name of this compound, as you would like it to appear in the Compound Table in Profiler
Compound Author The author of this compound, as you would like it to appear in the Compound Table in Profiler
Magnet Frequency (MHz) The frequency of NMR spectra, in megahertz (MHz), that this compound is intended to be used with when profiling.
Fit Style Specify whether this compound should use a peak-based or region-based fit style when it is profiled in Profiler. For more details, see “Compound Fit Style”.
Sample Concentration (mM) The concentration of this compound in the sample spectrum that you used as a reference (overlay) when building this compound signature. In millimoles per litre (mM). This value is only used for compounds with the peak-based fit style.
Chenomx Compound ID Chenomx compound ID associated with this compound
Pulse Sequence The pulse sequence used to acquire the sample spectrum that you used as a reference (overlay) when building this compound signature
Valid pH The pH value or range at which you expect this compound signature to be valid
Last Modified The date and time at which this compound was last modified (and saved).
UUID The Universally Unique Identifier used to uniquely identify this compound signature in the compound library. Newer and older versions of this compound should maintain the same UUID, but different compounds should always have distinct UUIDs.
Comment Any text comments associated with this compound signature; you can use this to record any additional information that you consider relevant

Tips and Tricks

  • For accurate quantification results, consider verifying the sample concentration that you enter using multiple independent techniques.

  • Entering the correct Chenomx Compound ID ensures that information appropriate to the compound appears in the Reference Panel. If your new compound has an ID that isn't recognized by the software, you can use “Reference Card Editor” to create your own reference card.

  • Make sure that any new signature that you create has its own distinct UUID. The UUID is used by Chenomx NMR Suite to identify different versions of the same compound, so only different versions of the same compound should share the same UUID.

Related Topics

  • “Reference Cards”

  • “Building Tools”

  • “Reference Card Panel (Sidebar)”

  • Chapter 9, Library Manager

  • “Reference Card Editor”

Information Panel

The Information Panel is always visible at the bottom of the Compound Builder window. It contains current information about the compound signature as you work on it. It lists clusters and peaks that you have created, describes the elements that you have currently selected and the environment on which your compound is based, and lets you access the edit dialog for individual clusters or peaks.

Tips and Tricks

  • You can select multiple peaks and clusters in the lists in the Information Panel. Hold down the Ctrl or Cmd keys while clicking on the desired peaks and clusters. Use Shift to select a range of peaks or clusters.

  • If you do not have a spectrum overlay, the Information Panel indicates that your compound signature is in the default environment. When you overlay a spectrum, the environment changes to match the overlay.

  • The Information Panel displays a warning if your spectrum overlay does not match the information that you provided in the Compound Details. You need to update the Compound Details to match the overlay or choose a new overlay spectrum to remove this warning.

Related Topics

  • “Spectrum Overlays”

  • “Building Tools”

  • “Compound Details”


Prev Up Next
8.2 Building Tools Home 8.4 Compound Fit Style
© 2021 Chenomx Inc.

Last modified: 30 Jun 2021