Table of Contents

  • Open this section 1. Notices and Trademarks
    • 1.1. Technical Support
    • 1.2. Disclaimer of Warranties and Liabilities
    • 1.3. Trademarks
  • Open this section 2. Introduction
    • 2.1. Running Chenomx NMR Suite
    • 2.2. Software Updates
    • 2.3. Tutorial and Sample Files
  • Open this section 3. Handling Samples and Spectra
    • Open this section 3.1. Sample Preparation
      • Preparing Filter Tubes for Sample Filtration
      • Filtering the Sample through Microcentrifuge Filter Tube
      • Internal Standard Solution
    • Open this section 3.2. Spectral Data Acquisition
      • Pulse Sequences
      • Required NMR Parameters
    • Open this section 3.3. Spectral Data Processing
      • Data Processed with Other Software
  • Open this section 4. Processor
    • 4.1. Overview
    • Open this section 4.2. Information Tools
      • Spectrum Details (Sidebar)
      • Processing History (Sidebar)
      • Calibration Tool
    • Open this section 4.3. Processing Steps
      • First Step: Line Broadening
      • Second Step: Phase Correction
      • Third Step: Baseline Correction
      • Fourth Step: Shim Correction
      • Fifth Step: Calibrate CSI
      • Sixth Step: Send to Profiler
    • Open this section 4.4. Optional Steps
      • Region Deletion
      • Reverse Spectrum
      • Define Custom CSI
      • Calibrate pH
      • Export as JCAMP-DX
  • Open this section 5. Profiler
    • 5.1. Overview
    • Open this section 5.2. Profiling Tools
      • Compound Table
      • Cluster Navigator
      • Enforce Transform Windows
      • Scale Concentrations
      • pH Tool
      • Colors/Stars/Pins/Remember Selection
    • Open this section 5.3. Manual Profiling
      • First Step: Identify Compounds
      • Second Step: Determine Compound Concentrations
      • Third Step: Profile Overlapped Regions in a Spectrum
    • Open this section 5.4. Automatic Profiling using a semi-automated approach
      • First Step: Cluster positioning using Compound Snapper
      • Second Step: Concentration optimization using Fit Concentrations
      • COMPLETE Autofit: fully automated profiling approach
    • Open this section 5.5. Importing and Exporting Data
      • Import Profile
      • Export Profiled Compounds
      • Export Compound Table
      • Batch Export
      • Send to Processor
  • Open this section 6. Library Manager
    • 6.1. Overview
    • Open this section 6.2. Library Tools
      • Compound Table
      • Quick Searches
      • Add Compounds
      • Export Compounds
      • Send to Compound Builder
      • Remove Compounds
      • Update Compounds
    • Open this section 6.3. Compound Set Tools
      • Compound Sets (Sidebar)
      • Automatic Compound Sets
      • Compound Sets
      • Smart Compound Sets
      • Rename Compound Sets
      • Remove Compound Sets
    • Open this section 6.4. Reference Card Editor
      • Required Details
      • Optional Details
    • Open this section 6.5. Information Tools
      • Reference Card Panel (Sidebar)
  • Open this section 7. Batching and Binning (PRO Only)
    • Open this section 7.1. Batching
      • Batch Import
      • Batch Process
      • Batch Edit
      • Batch Fit
    • 7.2. Spectral Binning
  • Open this section 8. Compound Builder (PRO Only)
    • 8.1. Overview
    • Open this section 8.2. Information Tools
      • Compound Details
      • Information Panel
      • Cluster Navigator
    • Open this section 8.3. Build a Compound
      • First Step: Sample Preparation and NMR Acquisition
      • Second Step: Process your Spectrum in Processor
      • Third Step: Import new CNX file into Compound Builder.
      • Fourth Step: Add Peaks, Define Clusters and Optimize Shapes
      • Fifth Step: Set Transform Windows
    • Open this section 8.4. Optional Steps
      • Compound Fit Style
      • Import Simulation
      • Generate Cluster for Region
      • New Compound
      • Manage Cluster IDs
      • pH Sensitivities
  • Open this section 9. Spin Simulator
    • 9.1. Overview
    • Open this section 9.2. Simulating Tools
      • New Simulation
      • Spin Systems
      • Spin Definitions
      • Spin Navigator
      • J-Modifiers
    • Open this section 9.3. Information Tools
      • Spin Definition (Sidebar)
      • Simulation Details
  • Open this section 10. The Basics
    • Open this section 10.1. File Management
      • Open Files
      • Importing Spectra
      • Saving Files
      • Closing Files
      • Undo and Redo
    • Open this section 10.2. Preferences
      • Change Columns
      • Display Options
    • Open this section 10.3. Sidebar
      • Legend
      • Files
      • Reference Cards
      • Quick Searches
      • Spectrum Details
      • Processing History
      • Compound Sets
      • Simulation
    • Open this section 10.4. Spectrum Graph
      • Spectrum Thumbnail
      • Select Region
      • Spectrum Overlays
      • Zoom Tools
      • Export Spectrum Image
      • Copy Spectrum Image to Clipboard
Chenomx NMR Suite User Guide logo

Search Results (close)

This is where the search results appear

3.3 Spectral Data Processing

Chenomx NMR Suite can import spectral data from a number of common sources. These include:

  • Agilent fid files and phasefiles

  • Bruker fid and 1r files

  • JEOL .jdf files

  • JCAMP-DX .jdx, .jcm and .dx files

  • NMRPipe .fid and .ft2 files

  • Mestrelab .mnova files (uncompressed format only)

Before you analyze a spectrum with Chenomx NMR Suite, you must properly process your raw spectral data using either the Processor module or one of the alternate software packages described in the next section. Note that the following steps can be partially or completely automated when using the Processor module.

  • Zero-fill your data, using the smallest power of 2 that is at least twice as large as the number of points acquired in the original spectrum (e.g., for 16000 points in the original spectrum, use zero-filling of 32K points).

    To do this in Processor, select Automatic in the import dialog under zero-filling.

  • Do not apply any transformations like sine bell or Gaussian functions to your spectra.

  • For the best results, you must properly phase and baseline correct all of your spectra.

  • For the best results, your spectra should have CSI linewidths of no more than 1.5 Hz. Use an appropriate combination of shim correction and line broadening to adjust the linewidths.

Data Processed with Other Software

If you prefer to process your spectra using a third-party software package, you need to ensure that the Fourier-transformed (frequency domain) data from your processed spectra is available for Chenomx NMR Suite to import. The processed data from the following software packages are supported:

  • VNMR and VNMRj (Agilent phasefile files)

  • XWIN-NMR (Bruker 1r files)

  • Delta (JEOL .jdf files)

  • NMRPipe (.ft2 files)

  • ACD/Labs software package. Export to the JCAMP-DX format (.jdx files).

  • Mestrelab .mnova files (uncompressed format only)

Spectra processed by most of these software packages requires no additional preparation before they can be imported. However, if you have spectra that were processed in older versions of VNMR or VNMRJ and you would like to retain your processing when you import them into Chenomx NMR Suite, you will need to copy each spectrum's phasefile into its fid folder.

To manually copy an Agilent phasefile into the fid folder

  1. Open the spectrum in VNMR and process the spectrum.

  2. Change experiments or quit VNMR, making note of the experiment number in which you have opened the spectrum (e.g., exp2).

  3. In a Solaris terminal window, copy the datdir folder into the mydata.fid folder where mydata.fid is your Agilent spectrum. mydata.fid is the folder that you need to access to open the spectrum using Chenomx NMR Suite.

    Use the following commands:

                    cd ~/vnmrsys/data/mydata.fid
                    cp -r ~/vnmrsys/expn/datdir .
                  

    where expn is the experiment number noted previously, and mydata.fid is the fid folder you want to access with Chenomx NMR Suite. In this example, expn would be exp2.

Note that it is possible to automate this process using VNMR if this is something you expect to do often. Consult your VNMR documentation for further information on automating tasks.


Prev Up Next
3.2 Spectral Data Acquisition Home Chapter 4. Processor
© 2023 Chenomx Inc.

Last modified: 27 Jun 2023