Table of Contents

  • Open this section 1. Notices and Trademarks
    • 1.1. Technical Support
    • 1.2. Disclaimer of Warranties and Liabilities
    • 1.3. Trademarks
  • Open this section 2. Introduction
    • 2.1. Running Chenomx NMR Suite
    • 2.2. Software Updates
    • 2.3. Tutorial and Sample Files
  • Open this section 3. Handling Samples and Spectra
    • Open this section 3.1. Sample Preparation
      • Preparing Filter Tubes for Sample Filtration
      • Filtering the Sample through Microcentrifuge Filter Tube
      • Internal Standard Solution
    • Open this section 3.2. Spectral Data Acquisition
      • Pulse Sequences
      • Required NMR Parameters
    • Open this section 3.3. Spectral Data Processing
      • Data Processed with Other Software
  • Open this section 4. Processor
    • 4.1. Overview
    • Open this section 4.2. Information Tools
      • Spectrum Details (Sidebar)
      • Processing History (Sidebar)
      • Calibration Tool
    • Open this section 4.3. Processing Steps
      • First Step: Line Broadening
      • Second Step: Phase Correction
      • Third Step: Baseline Correction
      • Fourth Step: Shim Correction
      • Fifth Step: Calibrate CSI
      • Sixth Step: Send to Profiler
    • Open this section 4.4. Optional Steps
      • Region Deletion
      • Reverse Spectrum
      • Define Custom CSI
      • Calibrate pH
      • Export as JCAMP-DX
  • Open this section 5. Profiler
    • 5.1. Overview
    • Open this section 5.2. Profiling Tools
      • Compound Table
      • Cluster Navigator
      • Enforce Transform Windows
      • Scale Concentrations
      • pH Tool
      • Colors/Stars/Pins/Remember Selection
    • Open this section 5.3. Manual Profiling
      • First Step: Identify Compounds
      • Second Step: Determine Compound Concentrations
      • Third Step: Profile Overlapped Regions in a Spectrum
    • Open this section 5.4. Automatic Profiling using a semi-automated approach
      • First Step: Cluster positioning using Compound Snapper
      • Second Step: Concentration optimization using Fit Concentrations
      • COMPLETE Autofit: fully automated profiling approach
    • Open this section 5.5. Importing and Exporting Data
      • Import Profile
      • Export Profiled Compounds
      • Export Compound Table
      • Batch Export
      • Send to Processor
  • Open this section 6. Library Manager
    • 6.1. Overview
    • Open this section 6.2. Library Tools
      • Compound Table
      • Quick Searches
      • Add Compounds
      • Export Compounds
      • Send to Compound Builder
      • Remove Compounds
      • Update Compounds
    • Open this section 6.3. Compound Set Tools
      • Compound Sets (Sidebar)
      • Automatic Compound Sets
      • Compound Sets
      • Smart Compound Sets
      • Rename Compound Sets
      • Remove Compound Sets
    • Open this section 6.4. Reference Card Editor
      • Required Details
      • Optional Details
    • Open this section 6.5. Information Tools
      • Reference Card Panel (Sidebar)
  • Open this section 7. Batching and Binning (PRO Only)
    • Open this section 7.1. Batching
      • Batch Import
      • Batch Process
      • Batch Edit
      • Batch Fit
    • 7.2. Spectral Binning
  • Open this section 8. Compound Builder (PRO Only)
    • 8.1. Overview
    • Open this section 8.2. Information Tools
      • Compound Details
      • Information Panel
      • Cluster Navigator
    • Open this section 8.3. Build a Compound
      • First Step: Sample Preparation and NMR Acquisition
      • Second Step: Process your Spectrum in Processor
      • Third Step: Import new CNX file into Compound Builder.
      • Fourth Step: Add Peaks, Define Clusters and Optimize Shapes
      • Fifth Step: Set Transform Windows
    • Open this section 8.4. Optional Steps
      • Compound Fit Style
      • Import Simulation
      • Generate Cluster for Region
      • New Compound
      • Manage Cluster IDs
      • pH Sensitivities
  • Open this section 9. Spin Simulator
    • 9.1. Overview
    • Open this section 9.2. Simulating Tools
      • New Simulation
      • Spin Systems
      • Spin Definitions
      • Spin Navigator
      • J-Modifiers
    • Open this section 9.3. Information Tools
      • Spin Definition (Sidebar)
      • Simulation Details
  • Open this section 10. The Basics
    • Open this section 10.1. File Management
      • Open Files
      • Importing Spectra
      • Saving Files
      • Closing Files
      • Undo and Redo
    • Open this section 10.2. Preferences
      • Change Columns
      • Display Options
    • Open this section 10.3. Sidebar
      • Legend
      • Files
      • Reference Cards
      • Quick Searches
      • Spectrum Details
      • Processing History
      • Compound Sets
      • Simulation
    • Open this section 10.4. Spectrum Graph
      • Spectrum Thumbnail
      • Select Region
      • Spectrum Overlays
      • Zoom Tools
      • Export Spectrum Image
      • Copy Spectrum Image to Clipboard
Chenomx NMR Suite User Guide logo

Search Results (close)

This is where the search results appear

4.2 Information Tools

Spectrum Details (Sidebar)

Menu Location View > Sidebars > Left Sidebar > Reference Card
Icon
Spectrum Details icon
Menu Location View > Sidebars > Right Sidebar > Reference Card
Icon
Spectrum Details icon

The Spectrum Details Sidebar view displays a summary of the calibration parameters for the current spectrum. It also shows the spectrum's acquisition details, including spectral width, magnet frequency, pulse sequence, and others. At the bottom of the view, there's also space for additional comments.

Tips and Tricks

  • You can edit a spectrum's calibration parameters using Processor's calibration tools.

  • A spectrum's acquisition details cannot be edited.

  • You can edit a spectrum's comments at any time. You must save the spectrum to retain your changes.

Processing History (Sidebar)

Processing spectra in Processor does not alter your original spectral data. Every processing effect that you add to a spectrum acts as a layer modifying the display of your original data. All of these effects are completely reversible, and are tracked in the Processing History Sidebar view.

While processing a spectrum, you may want to review, edit or reverse one or more of the processing layers that you have already applied. The Processing History maintains a list of every processing layer that you have applied to the current spectrum using Processor. You can review this list to find out the parameters used in each layer, like phase angles or shim correction parameters, step back through past layers to reverse their effects, or edit a layer.

When you import a processed spectrum, Processor imports phase correction, baseline correction and other processing that you may have applied in other processing software. The imported processing effects appear in the Processing History as a layer called External Processing. The External Processing layer is not reversible, nor can you remove or edit it.

Menu Location View > Sidebars > Left Sidebar > Processing History
Icon
Processing History icon
Menu Location View > Sidebars > Right Sidebar > Processing History
Icon
Processing History icon

How do I review and remove processing layers?

  1. Switch to the Processing History view in the Sidebar.

  2. Click the name of a processing layer to review its associated parameters; they appear in the Details box below the list.

  3. Click the Clear button to remove the processing layer that is currently selected.

    Removing a processing layer will also remove all subsequent processing layers.

How do I edit the most recent processing layer?

  1. Switch to the Processing History view in the Sidebar.

  2. Click the Edit button to edit the processing layer that is currently selected.

  3. When you have finished your changes, click the Accept button.

    Editing a processing layer will cause all subsequent processing layers to be removed.

Tips and Tricks

  • The Processing History only tracks processing effects, including phase correction, baseline correction, shim correction, water deletion and line broadening. Changes to spectrum metadata, such as the spectrum details or CSI and pH settings, do not appear in this panel.

  • If you have just accidentally removed or edited a layer in the Processing History, you can use the Undo button to restore it.

Related Topics

  • “Importing Spectra”

  • “Processing Steps”

  • “Batch Import”

Calibration Tool

It is possible to calibrate the frequency axis manually by right-clicking anywhere in the spectrum and selecting “Set new frequency at this location” in the contextual menu that appears. This will bring up an interface will to specify a resonance frequency at the clicked location.